Features
1. Over range indication, test lead connection alarm
2. TEST button for fast capture of measurement values
3. 20-group data storage/recall
4. Backlight
5. Data hold
6. Auto power off/battery check
7. Earth voltage measurement
Specifications
Range
Model
UT526
Insulation Resistance (Ω)
Test Voltage
250V/500V/1000V
±10%
250V
0.05MΩ~200MΩ
±(5%+5)
500V
0.05MΩ~300MΩ
±(5%+5)
1000V
0.05MΩ~500MΩ
±(5%+5)
Load Current
250V (R=250KΩ) 1mA
±10%
500V (R=500KΩ) 1mA
±10%
1000V (R=1MΩ) 1mA
±10%
Short Circuit Current:
<2mA
√
RCD
Operational Voltage (Freq.)
220V (45Hz--65Hz)
±10%
Test Current
10mA/30mA/100mA/300mA
0~20%
Trip Time
0ms~2000ms, 1Δn Genetal (10mA)
±(5%+2)
0ms~500ms, 1Δn Genetal (300mA)
0ms~300ms, 1Δn Genetal (100mA, 300mA)
Low Resistance Continuity
Range
0.00Ω~2000Ω
±(2%+5)
Test Voltage
Around 5.0V
√
Test Current
>200mA (R<2Ω)
√
Voltage Mesurement (V)
DC Voltage
0~440V
±(5%+2)
AC Voltage
0~440V
Frequency (For reference only)
√
Features
Max Display
9999
Manual Range
√
Phase Switch (RCD)
0°and 180°
√
Low Battery Indication
√
Automatically Selects DCV or ACV
√
Red Warning Lights
√
General Characteristics
Power
1.5V Alkaline Batteries (LR6)×6
LCD Size
71mm X 34mm
Product Color
Red and grey
Product Net Weight
380g
Product Size
160mm X 100mm X 71mm
Standard Accessories
Test Lead, Batteries, Carrying Bag, Alligator Clip
Standard Individual Packing
Gift Box, English Manual
Standard Quantity Per Carton
20pcs
Standard Carton Measurement
400mm X 430mm X 335mm (0.063CBM per export carton)
Standard Carton Gross Weight
23.1kg